Your current location:HOME > Product > Induction Furnace > induction furnace >

5T induction furnace

Introduce:Provide 5T induction furnace price, provide 5T induction furnace body structure selection method, provide relevant configuration such as transformer, incoming cable, incoming line voltage, water cooling system selection method and calculation method, 5T induction furnace energy consumption determination method.
  • Introduction
  • Consultation

5T induction furnace consists of:

3000kw intermediate frequency power supply - compensation capacitor cabinet - aluminum shell or steel shell furnace body - hydraulic tilting furnace system - remote control box - ZXZ-N320T ( 70/250) closed loop cooling tower. The 5T induction furnace has protection systems such as overvoltage, overcurrent, water temperature, water pressure, short circuit and grounding. The operation panel has various parameters such as working parameter display table and display working status, and there are indications such as fault and temperature.

5T induction furnace price

The price of the 5T induction furnace is calculated according to the power of the intermediate frequency power supply and the volume of the furnace body. Different configuration prices vary. This price is for reference only. Contact us will have a very low price, please consult the specific price.Firstfurnace@gmail.com   

Serial number

Item name

Specification model

unit

Quantity

Price ¥

1

3000KW medium frequency power supply cabinet

3000KW/5T/500HZ

station

1

265000

2

Compensation capacitor cabinet

2 . 0 - 4 000-1S

set

1

95000

3

5T furnacesteel shell

GW- 5T

set

1

250000

4

Water cooled cable

LHSD- 600

set

4

30000

5

Model

5T furnace dedicated

only

1

3000

Total: ¥ 643,000

 

5T induction furnace furnace structure selection summary table

5T induction furnacebody

Steel shell furnace

Aluminum shell furnace

Furnace shell material

Steel structure

Aluminum structure

Furnace tilting mechanism

Hydraulic cylinder

Reducer

Furnace hydraulic pumping station

Have

no

Yoke

Have

no

Furnace cover

Have

no

Leakage alarm

Have

no

Energy consumption

520Kw.h/t

600Kw.h/t

life

10 years

4-5 years

Furnace price of 5Tinduction furnace

high

low

     5T induction furnace technical parameters

Serial number

project

unit

parameter

1

Specification model


KGPS- 3 0 00KW- 5T

2

Rectification method


12-pulse rectifier

3

Transformer capacity

KVA

3150

4

Transformer primary voltage

V

10k

5

Transformer secondary voltage

V

500 × 2

6

Input voltage

V

Double 50 0

7

Input Current

A

604 × 2

8

Power frequency

Hz

50

9

DC voltage

V

1350

1 0

DC

A

2200

1 1

IF voltage

V

3 0 00

1 2

Output frequency

Hz

500

1 3

Output Power

KW

3 000

1 4

Power Efficiency


0.95

1 5

Grid power factor


0.9 2

1 6

Start success rate


1 00 % (in any case)

IMG_20171214_184310.jpg

How to choose 5T induction furnace transformer capacity?

        The relationship between the capacity of the intermediate frequency induction furnace transformer and the power of the SCR intermediate frequency power supply is: the value of the transformer capacity = the value of the intermediate frequency power supply , and the transformer of 2000KVA is selected . In order to reduce the interference of harmonics, the special purpose machine is dedicated to one medium frequency induction furnace. Configure a dedicated rectifier transformer.

 

How to choose the 5T induction furnace incoming line voltage? 
5T induction furnace using an SCR 3500KW frequency power supply 6 is generally a three-phase or six-phase clock pulse wire 12 60V, 50Hz industrial use, arranged pulse rectifier 6-pulse or 12.

 

Configure 12- pulse double rectification   How to choose the 5T induction furnace incoming line voltage?

1 ,   5T induction furnace incoming line voltage selection is 660v , 575v , double rectification 380v ;

2 , do not blindly pursue high voltage (some   5T induction furnace 3500KW uses 900V line voltage), energy saving has been achieved since low current, high voltage is easy to shorten the life of electrical components, copper bars, cables are tired, and the life of electric furnace is greatly reduced.

 

How to calculate the cable of 5T induction furnace ?

For example: IF power induction furnace 5T maximum power 3000KW, 3500KW 500V line voltage of the power line IF sectional area of the copper plate: 1000mm 2 within 10 meters of copper 100x10mm copper.

 

How large is the closed cooling tower calculation method for the 5T induction furnace medium frequency induction furnace ?

Choice: integrated layered tower closed - loop water cooling tower ZXZ-N320T ( 70/250)

Select a mixed water tower to calculate a closed loop cooling tower with a formula of 3000kw × 0.5 × 860 ÷ 5000 = 258T .

Select an integrated layered cooling tower to separately cool the intermediate frequency power supply and the furnace body. The cooling tower tonnage selection formula of the intermediate frequency frequency power supply is: 3000kw × 0.12 × 860 ÷ 5000=60T . The cooling tower tonnage selection formula of the furnace induction coil is: 3000kw × 0.45 × 860 ÷ 5000=240T , the integrated layered closed-loop cooling tower is selected as 60T +240 T=300T should be selected as a 300T cooling tower, the corresponding model is: ZXZ-300T ( 60/240)

 

How to arrange 5T induction furnace ? Please see the figure below to answer

image.png 

What information does the customer need to provide to the supplier before purchasing the 5T induction furnace ?

1. The medium frequency induction furnace must have room for layout, and it is necessary to provide the area and layout of the plant.

2. The customer needs to provide the capacity of the transformer, the magnitude of the incoming line voltage, and the frequency of the incoming line voltage.

3. The medium frequency induction furnace needs water cooling equipment, and the configuration of the medium frequency induction furnace contains water cooling equipment.

4. The structure of the medium frequency induction furnace has a steel shell body and an aluminum shell body, which requires the customer to specify the furnace structure.

5. The power supply of the medium frequency induction furnace is the intermediate frequency power supply. The line structure of the intermediate frequency power supply is divided into the inverter parallel and the inverter series structure. The inverter series structure is energy-saving, the power factor is 0.98, and the line is stable. The inverter parallel structure is of the common type with a power factor of 0.92, which requires the customer to specify the line structure.

What are the technical requirements for cooling water in each cooling part of 5T induction furnace ?

Different frequency induction furnace cooling portion cooling requirements different from water, an induction coil, a capacitor of the cooling water system using industrial cooling water pressure, the pressure is maintained at 0.15-0.2mpa, water temperature maintained at 20-35 ° C inlet water temperature temperature below 55 ° C.

How large is the 5T induction furnace using a reservoir?

The 5T induction furnace consists of two parts, which are divided into intermediate frequency power supply and furnace body. The same reservoir can be used to cool the outlet water temperature to be controlled within 55 ° C. The reservoir is 60 cubic meters : the cooling effect is poor, it is easy to block, and the general investment The minimum, the cooling effect is general.

Determination of energy consumption of 5T induction furnace

The higher the power of the medium frequency induction furnace, the more power is saved, the energy consumption of the molten iron furnace: 5 2 0KW.h/t temperature 1550 ° C , energy consumption of molten steel furnace 550 KW.h/t temperature 1550 ° C. 


Understand Wikipedia: induction furnace
Recommended Reading: induction furnace
Recommended Reading: induction furnace

PREV:500kg induction furnace

NEXT:No More Articles.

Related Articles
Related Video