Equipment electrical maintenance knowledge

Steps to quickly check the failure of the intermediate frequency furnace summarized

Time: 2019-07-01

Steps to quickly check the failure of the intermediate frequency furnace summarized

In the process of using the intermediate frequency furnace, the manufacturer always has such problems. As an electrician who specializes in repairing the intermediate frequency furnace, how to quickly check and determine the cause of the failure when encountering the failure of the intermediate frequency furnace, so as to formulate the maintenance plan, this is the test of the intermediate frequency electrician. Important indicator. The following is a method for quickly checking and repairing the fault of the intermediate frequency induction furnace summarized by the old electrician who is responsible for the electric furnace maintenance for 15 years.

Under normal circumstances, the operator can divide the faults in the intermediate frequency induction furnace into two types according to the fault phenomenon. One is that it cannot be started at all, and the other is that it cannot work normally after starting. According to the general principle, after the fault occurs, the entire system of the intermediate frequency furnace must be thoroughly checked when the power is turned off to ensure safe operation.

Such a comprehensive inspection is divided into the following contents: The first one is the power supply. It is necessary to measure the switch of the main circuit with a multimeter and whether there is current passing after the fuse is turned on. This method can eliminate the possibility of disconnection of these components. .

Next, check that the rectifier is in normal operation. The rectifier uses a three-phase full-control bridge rectifier circuit. This circuit includes six fast-blow fuses, six thyristors, six pulse transformers, and one freewheeling diode.

Finally check the fuse out, there is a red indicator on the fast fuse. When normal, the indicator shrinks into the outer casing, and it will pop up when it melts and burns. However, some indicators are tight when installed, so they do not pop up after being melted but are stuck inside, so for safety reasons you should still use a multimeter to test.

Through the above aspects of detection, it is basically possible to quickly locate the faulty component, and then formulate a maintenance plan according to the specific fault phenomenon.