1. The sensor bracket has a total of 6 units between the roller tables for mounting the sensor.
2. In order to prevent the bracket from being heated, the sensor bottom plate and the top plate of the bracket are made of an epoxy board.
3. For steel pipes of different diameters, the corresponding sensors need to be replaced and the center height can be adjusted.
4. The bolt holes of the sensor are made into a thick hole for easy adjustment.
5. The center height of the sensor can be adjusted by the stud nuts in the sensor mounting plate.
6. The two connecting copper bars in the lower part of the sensor are connected with the water-cooled cables from the capacitor cabinet by four stainless steel (1Cr18Ni9Ti) bolts.
7. The inlet and outlet pipes of the sensor are connected with the main pipe by quick-change joints and hoses, which are not affected by the position error, so the quick connection of the sensor waterway can be realized.
8. The sensor can be quickly replaced, each replacement time is less than 10 minutes, and the mobile trolley is equipped for replacement of the sensor.
9. The furnace is designed with a fixed bracket that can be adjusted up and down. Through the adjustment of the manual worm gear lifter, the center lines of the furnaces of different specifications can be realized at the same height. It can effectively ensure that the steel pipe passes through the inductor smoothly without colliding with the furnace body. This device has an adjustment range of ±50 and is suitable for φ95-φ130 steel pipe.