15KW electromagnetic Heating stove

Introduce:15KW electromagnetic heating furnace basic selection method, 15KW electromagnetic heating furnace description and schematic diagram, 15KW electromagnetic heating furnace applicable range, electromagnetic induction heating furnace operating costs
  • Introduction
  • Consultation


 Three-phase 5KW/380V , 8KW/380V , 10KW/380V , 15KW/380V electromagnetic heating controller. It is a digital electromagnetic heating system developed by the company based on the company's fifth-generation DSP control platform. Compared with the previous electromagnetic heating control board, it adopts all-digital operation processing, German Infineon magnetic drive, and all-digital phase-locking tracking technology. It has the characteristics of high performance stability, high thermal efficiency, easy installation and low failure rate. The application is very wide, the appearance is beautiful, the installation is convenient, the debugging is simple, and the application is reliable. It can be widely used in the heating furnace, mechanical plastic, rubber equipment, chemicals, molds, commercial induction cooker, a variety of heating pipes, and the like conveying surface heating oil heating industries.

Principle of electromagnetic heating heating furnace 
Introduction to frequency conversion electromagnetic heating furnace: 
The electromagnetic heating furnace adopts the principle of electromagnetic induction heating, which uses AC rectification to convert it into DC power and then inverts it into a high-frequency alternating current, which acts on the inductor coil to generate an alternating magnetic field, so that the furnace body generates numerous small eddy currents, and the furnace is heated by eddy current collision. Body, so that the water in the furnace body is heated, the water and the coil are larger than   20mm insulation and heat insulation material can achieve 98% thermal efficiency , environmental protection safety, short warm-up time and fast heating speed. The electromagnetic heating furnace system comprises: a frequency conversion electromagnetic heating controller, an intelligent operation control system, an electromagnetic coil, a heating furnace body and a protection circuit.  



image.png 

Basic selection method of 100-160kW electromagnetic heating furnace

model

unit

SD-100KW

SD-120KW

SD-140KW

SD-160KW

rated power

KW

100KW

120KW

140KW

160KW

Rated current

A

150

180

210

240

Line voltage /frequency

V/HZ

380/50

380/50

380/50

380/50

Line cross section

Mm2

3 × 35

3 × 35

3 × 50

3 × 75

Protection level

IP

33

33

33

33

Thermal conversion efficiency

%

≧ 98

≧ 98

≧ 98

≧ 98

Shell heat dissipation

%

≦ 2

≦ 2

≦ 2

≦ 2

Heating Z large capacity

L

1800

2000

2500

3000

Heating Z pressure

Mpa

0.25

0.25

0.25

0.25

Pump Z small flow

L/min

120

144

168

192

Water tank capacity

L

100

120

140

160

Heating Z high temperature

OC

90

90

90

90

Holding temperature

OC

5

5

5

5

Hot water yield65OC

L/min

33

40

46

53

Dimensions

Mm

1500 × 800× 800

1500 × 800 ×800

1500 ×800 × 800

1500 × 800× 800

Access interface

DN

40

40

40

40

Heating area

M2

1000-1300

1200-1500

1400-1800

1600-2000

Heating space

M3

3400-4500

4000-5500

5000-7000

6000-8000

Meter measurement selection

A

Optional reasonable current transformer, three-phase watt-hour meter 1.5-6A

 

Advantages of electromagnetic heating furnace 
1 , high heat conversion rate

Using electromagnetic induction heating technology, high-frequency electromagnetic eddy current heating, heat conversion rate of up to 98% , can drive the radiator. The floor heating pipe dissipates heat, the heating rate is extremely high, and the efficient and quick 1-3 minutes outlet temperature reaches 60degrees.

2 , energy saving and environmental protection

Electromagnetic induction heating is more than 30% energy saving than ordinary resistance heating . It responds to the national “coal to electricity” blue sky environmental protection policy, cleansing electric energy, and truly achieves zero emissions and zero pollution.

3 , electromagnetic heating truly achieve the separation of water and electricity, avoid the safety hazards of ordinary electric boilers, product constant power, soft start control, start no current impact, and have over-current, dry burning, over-temperature and other early warning functions, use more Safety.

4 , intelligent temperature control

Support PLC programmable operation, support RS485 communication, human-machine interface interaction, remote WIFI remote control using microcomputer programmable controller control, power, water temperature controllable, timed temperature, convenient and convenient.

5 , stable quality and long service life

The heating element of the electromagnetic heating furnace does not heat up, but the furnace itself is rapidly heated, which greatly prolongs the service life of the heating element, and the overall design life is 50 years.

6 , low operating costs

Electromagnetic heating has high efficiency, fast heating and no scaling. Maintenance free. Set your own heating time, temperature standards, and operating costs yourself. Greatly reduced operating costs.

7 , easy to install, practical and convenient

The refined design, butt access, water outlet, the user's original radiator, water heater, floor heating pipe, no need to replace, can be connected to run. When you turn it on, customers can set it according to their needs. The machine automatically remembers the memory, and each time it is started, it will be set according to the memory, and the intelligent automatic constant temperature operation

8 , healthy and comfortable

Frequency conversion electromagnetic induction heating heating, fast heating, high thermal efficiency, good thermal stability, air is not dry, air is more comfortable, no air conditioning disease caused by microorganisms generated by air conditioning, improved outdoor temperature is low, air conditioning heating does not work, up to Less than ideal heating effect

9 , small size

The electromagnetic heating furnace is small in size and beautiful in appearance. It can be installed in the living room, bedroom, office and other places. Minimize the possession of space.

10 , a wide range of applications

Electromagnetic heating furnaces have a wide range of applications. They can be used for central heating or household heating. From residential quarters to self-built houses, from enterprises and institutions to ordinary shops, all places that require heating, such as hotels, schools, units, and houses, are involved.

Electromagnetic heating stove product selection table

Model item

unit

SD -10kW

SD -12kW

SD -15kW

SD1 -20kW

SD1 -30kW

SD1 -40kW

rated power

kW

10kW

12kW

15kW

20kW

30kW

40kW

Rated current

A

15

18.2

27.2

36.3

45.4

60.8

Supply voltage /frequency

V/Hz

380/50

380/50

380/50

380/50

380/50

380/50

Power line cross-sectional area

Mm2

≥4

≥4

≥6

≥10

≥10

≥16

Electrical protection level

IP

33

33

33

33

33

33

Thermal conversion efficiency

%

≥98

≥98

≥98

≥98

≥98

≥98

Shell heat dissipation

%

≤2

≤2

≤2

≤2

≤2

≤2

Heating system maximum capacity

L

185

222

278

370

555

740

Heating system maximum pressure

Mpa

0.2

0.2

0.2

0.2

0.2

0.2

Pump with minimum flow

L/min

16

20

25

32

50

67

Expansion tank capacity

L

10

12

15

20

30

40

Heating maximum temperature

°C

90

90

90

90

90

90

Low temperature protection temperature

°C

5

5

5

5

5

5

Hot water yield 65 °C

L/min

3.25

3.9

4.88

6.5

9.8

13

Dimensions

Mm

1150*800*400

1150*800*400

1150*800*400

1150*800*400

1150*800*400

1800*900*400

Access interface

DN

40

40

40

40

40

40

Heating area

M2

100-120

120-150

150-180

200-240

300-360

400-480

Heating space

M3

320-400

385-600

530-670

640-800

960-1200

1280-1600

Meter selection

A

15A (60A)

15A (60A)

15A (60A)

15A (60A)

15A (60A)

30A (100A) three phase


Model item

unit

SD -50kW

SD -60kW

SD -70kW

SD -80kW

SD -100kW

XHY -CN-120kW

SD -140kW

rated power

kW

50kW

60kW

70kW

80kW

100kW

120kW

140kW

Rated current

A

75

90

105

120

150

180

210

Supply voltage /frequency

V/Hz

380/50

380/50

380/50

380/50

380/50

380/50

380/50

Power line cross-sectional area

Mm2

3×25

3×25

3×25

3×35

3×35

3×50

3×50

Electrical protection level

IP

33

33

33

33

33

33

33

Thermal conversion efficiency

%

≥98

≥98

≥98

≥98

≥98

≥98

≥98

Shell heat dissipation

%

≤2

≤2

≤2

≤2

≤2

≤2

≤2

Heating system maximum capacity

L

920

1100

1290

1480

1840

2200

2576

Heating system maximum pressure

Mpa

0.2

0.2

0.2

0.2

0.2

0.2

0.2

Pump with minimum flow

L/min

60

72

84

96

120

144

168

Expansion tank capacity

L

50

60

70

80

100

120

140

Heating maximum temperature

°C

90

90

90

90

90

90

90

Low temperature protection temperature

°C

5

5

5

5

5

5

5

Hot water yield 65°C

L/min

16.25

19.5

22.75

26

32.5

39

45.5

Dimensions

Mm

1800*900*400

1800*900*400

1800*900*400

1800*900*400

1800*900*400

1800*900*400

1800*900*400

Access interface

DN

40

40

40

40

40

40

40

Heating area

M2

500-600

600-700

700-800

800-900

1000-1300

1200-1500

1400-1800

Heating space

M3

1720-2390

2100-2850

2580-3560

1460-1810

3450-4780

4150-5740

5150-7100

Meter selection

A

30A (100A)three phase

Need professional electrician to install transformers reasonably, three-phase electric meter 1.5-6A


Model item

unit

XHY -CN-160kW

SD -180kW

SD -210kW

XHY -CN-240kW

SD -360kW

SD -480kW

rated power

kW

160kW

180kW

210kW

240kW

360kW

480kW

Rated current

A

240

270

315

360

540

720

Supply voltage/ frequency

V/Hz

380/50

380/50

380/50

380/50

380/50

380/50

Power line cross-sectional area

Mm2

3×75

3×75

3×75

3×95

3×120

3×180

Electrical protection level

IP

33

33

33

33

33

33

Thermal conversion efficiency

%

≥98

≥98

≥98

≥98

≥98

≥98

Shell heat dissipation

%

≤2

≤2

≤2

≤2

≤2

≤2

Heating system maximum capacity

L

2960

3300

3870

4400

6600

8800

Heating system maximum pressure

Mpa

0.2

0.2

0.2

0.2

0.2

0.2

Pump with minimum flow

L/min

192

216

252

288

432

576

Expansion tank capacity

L

160

180

210

240

360

480

Heating maximum temperature

°C

90

90

90

90

90

90

Low temperature protection temperature

°C

5

5

5

5

5

5

Hot water yield 65 °C

L/min

52

58.5

68.25

78

117

156

Dimensions

Mm

1800*900*400

1800*900*750

1800*900*750

1800*900*750

1800*900*750

1800*900*750

Access interface

DN

40

80

80

80

80

80

Heating area

M2

1600-2000

1800-2200

2100-2500

2400-3000

3600-4300

4800-5500

Heating space

M3

2920-3620

6300-8550

7750-10700

8300-11480

12450-17220

16600-22960

Meter selection

A

Need professional electrician to install transformers reasonably, three-phase electric meter 1.5-6A

Operating cost of electromagnetic induction heating furnace

Electromagnetic heating operation cost calculation  

The electricity heating operation cost of one square meter in the whole heating period can be calculated according to the following formula:

Unit area heat load × heat load coefficient × daily working time × heating period days × electricity price unit price = heating cost per unit area of the entire heating period

Electromagnetic heating operation status can be divided into the following types:

( 1 ), the user is at home for a long time, the electric heating furnace is running 24 hours a day, in order to save operating costs, the heating temperature at night is appropriately lowered.

      The electromagnetic heating cost is: 0.05kw/m2 × 0.6 × 10 hours × 120 days × 0.52 yuan / degree = 18.72 yuan /   M2

( 2 ), office workers, users only at noon, at home at night, electric heating furnace intermittent operation in 3 periods.

The electromagnetic heating cost is: 0.05kw/   M2 × 0.6 × 6 hours × 120 days × 0.52 yuan / degree = 11.23 yuan /   M2

( 3 ), office, 5- day work system, heating only from Monday to Friday, electric heating stove running during the day, the rest of the time running in anti-freeze state.

The electromagnetic heating cost is: 0.06kw/   M2 × 0.6 × 6 hours × ( 120 days × 5/7 ) × 0.52 yuan / degree = 9.62 yuan /   M2

( 4 ), the school, in addition to the five- day work week , there is a 35- day holiday, heating time is relatively short.

The electromagnetic heating cost is: 0.06kw/   M2 × 0.6 × 6 hours × [ ( 120 days   -   35 days) × 5/7 × 0.52 yuan / degree = 6.81 yuan /   M2

Using the above calculated value × actual heating area (saleable area) of the room, it is possible to calculate the operating cost of the entire heating period. If the user reasonably adjusts or closes the heating device that does not require a heating room (such as an unused room, bathroom or kitchen), the actual The heating area is reduced accordingly, and the heating costs are reduced accordingly.

Note: 0.07kw/   M2 is a standard energy-efficient building requiring winter heating electric load of 55 - 70w /   M2 , electromagnetic heating is more than 35% energy saving than ordinary electric heating ,   0.52 yuan / kW is the current unit price of electricity in Beijing. If the peak and valley electricity price can be calculated at an average of 0.35 yuan / kWh, the user's heating cost for a long time at home is 12.6 yuan, and the heat load coefficient of 0.6 means the initial period of the heating period. At the end of the period, the indoor heat load is small, and during the coldest period of the heating period, the indoor heat load is large, with an average of 0.6 . Actual heating area: The building area is multiplied by 0.78 , minus the practical area of the room without heating.

The electromagnetic heating furnace is similar to electric water heaters and air conditioners. The working time is proportional to the heat load demand of the room. The electricity price per unit, heating cycle and electric heating furnace work time are different in each region, such as the northeast region. The weather is cold, but his house insulation measures are better (the wall thickness is 0.5 meters, the external insulation material, the window is double-vacuum glass), and the electricity bill is relatively cheap.


Understand Wikipedia: induction heating
Recommended Reading: electromagnetic Heating stove
Recommended Reading: induction heater

PREV:No More Articles.

NEXT:30KW electromagnetic heating furnace

Related Articles
Related Video