Your current location:HOME > Technical > Equipment technical parameters >
Equipment technical parameters

3T intermediate frequency furnace technical parameter selection table

Time: 2019-06-29

project

unit

3t melting furnace data

Remarks

Electric furnace parameters

Rated Capacity

t

3.0


Maximum capacity

t

3.3


Lining thickness

Mm

120


Inductive circle

Mm

980

Sensor wall thickness 4mm

Induction loop height

Mm

1230


Maximum working temperature

°C

1750


Electrical parameters

Transformer capacity

KVA

2500


Transformer primary voltage

KV

10


Transformer secondary voltage

V

660


IF power supply rated power

KW

2000


IF power supply output voltage

V

1300


Coil voltage

V

2600


Rated operating frequency

Hz

500


Power conversion efficiency

%

96


Start success rate

%

100


Comprehensive parameter

Melting rate ( heating to1600 °C )

t/h

≥ 3.0


Melting power consumption( heating up to 1650 °C )

KW • h/t

610-640


Working noise

Db

≤ 75


Hydraulic system

Hydraulic station capacity

L

350

Double machine double pump

Work pressure

MPa

11


Hydraulic medium


Hydraulic oil


Cooling water system

Cooling water flow

M3/h

60


Inlet temperature

°C

5-35


Effluent temperature

°C

35-55


Cooling water pressure

MPa

0.2-0.35