Detailed introduction
name: | Ds- 2000 induction heater |
power: | 200KVA |
Voltage and current: | 380V/520A |
Adapt to the inner diameter of the workpiece: | φ > 300mm |
Maximum workpiece outer diameter: | 4000mm |
Maximum workpiece width: | 1000mm |
Maximum workpiece load: | 20000KG |
Machine quality: | 4000KG |
Dimensions: | 360×120×200cm |
Heating rod configuration: | 200mm |
Ds -2000 Series
power | 200 KVA | temperature control | 0 - 240 ° C | Free warranty | 3 years |
Voltage | 380V / 50Hz | time control | 0 - 99'59'' | time control | Have |
Current | 520A | Rotating device | Yes | Continuous installation | Have |
Adapt to bearing inner diameter | φ >300mm | Horizontal heating bracket | Have | Temperature retention | Have |
Maximum bearing outer diameter | 4000mm | Movable | Yes | Automatic demagnetization | Have |
Maximum bearing width | 1000mm | Magnetic temperature probe | Yes | Automatic power reduction | Have |
Maximum bearing weight(Kg) | 20000 | Column height | 1000mm | Control panel (display ) | digital |
Other parts(Kg) | 3000 | Column size(mm) | 300×1000 | Heating rod standard | 200×200( mm ) |
Host weight | 4000Kg | Dimensions(cm) | 360×120×200 |
I. Overview
This product is used in conjunction with metal parts. Using the principle of thermal expansion and contraction, the metal parts are heated to an aperture sufficient to easily reach the axial position without causing any damage to the workpiece or the shaft.
The whole process of heating the workpiece to the workpiece is controlled by a microcomputer. Safe, reliable, efficient, easy to use, and set three operating modes (time control mode, temperature control mode and temperature hold mode) for the operator to choose.
Second, technical performance
(1) Working conditions
1 , the power supply voltage exchange 380 ( V )
2 , the maximum working current is 520 amps ( A )
3 , working frequency 50 ~ 60 Hz ( Hz )
4 , power 200.0KVA
(2) Working mode and advantages
1. Temperature control mode, set the measurement range from 0 to 240 °C.
2 , time control mode, set the measurement range 0~99 minutes and 59 seconds.
3. Temperature hold: Press the temperature hold button to enter the temperature hold state when the heated workpiece reaches the set temperature.
4. This product has the function of soft start during operation, which reduces the impact on the device during start-up and prolongs the service life; when the power is off, the soft stop mode is adopted to realize the function of automatically removing the residual magnetism of the workpiece.
(3) Digital display and audio prompts
1. Temperature setting, the heating device preset temperature value is 110 °C.
2. The time setting can be set arbitrarily within 99 minutes and 59 seconds.
3. At the end of each heating cycle, there is an audio signal prompt.
4. When the sensor is not working normally, the device has an audio signal prompt.
(4) Heating the workpiece range
Heating workpiece inner diameter > 300mm
Heating workpiece outer diameter < 4000mm
Heating workpiece maximum thickness 1000mm
Third, the operating instructions
1. Ensure that the power supply voltage is accurate.
2. Plug the unit's power plug into a power outlet. When the switch on the side of the machine casing is turned on, the digital tube lights up and the temperature is 110 °C. At this time, the heating device is in the temperature control mode.
3. Press ▲▼ key to select the temperature value of the workpiece to be heated.
4. Press the START button to start the heating device to heat the heated workpiece.
5. When the heating device works to the set temperature value, the device will automatically stop and have an audible prompt.
6. If the temperature hold function is required , just press the temperature to keep it before proceeding to the fourth operation.
7. If the time control mode is adopted, the time control mode can be entered by pressing the button after power on, and the time setting value can be arbitrarily selected within 99 minutes and 59 seconds. Press ▲▼ key to select the heating time for the workpiece. Press the START button to start the heating deviceafter the selected time . This timing method is countdown. When the heating device is operated for a set time, there is an audible prompt and it automatically stops. (Time setting method: press the key once to enter the "seconds" is set, press the key twice to enter the "minute" setting each press "▲ ▼" key once, to increase or decrease the clock 1, and hold. Do not move, the clock changes continuously.)
8. When using the time control mode, there is no need to use the temperature sensor. In this case, the temperature sensor should be removed from the workpiece to prolong the service life of the sensor.
Fourth, matters needing attention
1 , can only be used at 380V voltage.
2. It is strictly forbidden to start the heating device with no load.
3. Make sure the cap is in place before pressing START .
4. When using the temperature control mode, the sensor should be reliably adsorbed on the inside of the workpiece, and the contact surface should be kept clean. If the E03 prompt appears: Please check if the sensor is connected or the workpiece is too large; if repeated prompts: Please check if the sensor is damaged.
5. Items that are susceptible to magnetic fields should be kept away. For example, cardiac pacemakers, hearing aids, magnetic tapes, magnetic cards, etc., the safety distance is 2 meters.
Copyright© 2007-2013 NO.6 Electric Mall All Rights Reserved